Jetzt anpassen und kaufen
396,00 €
exkl. USt.
Konfigurieren
Norm

ÖVE/ÖNORM EN 60079-14

Ausgabedatum: 2014 11 01

Explosive atmospheres - Part 14: Electrical installations design, selection and erection (IEC 60079-14:2013) (english version)

This part of the IEC 60079 series contains the specific requirements for the design, selection, erection and initial inspection of electrical installations in, or associ...
Weiterlesen
Gültig
Herausgeber:
Austrian Standards International
Format:
Digital | 150 Seiten
Sprache:
Englisch
This part of the IEC 60079 series contains the specific requirements for the design, selection, erection and initial inspection of electrical installations in, or associated with, explosive atmospheres. Where the equipment is required to meet other environmental conditions, for example, protection against ingress of water and resistance to corrosion, additional protection requirements may be necessary. The requirements of this standard apply only to the use of equipment under standard atmospheric conditions as defined in IEC 60079-0. For other conditions, additional precautions may be necessary, and the equipment should be certified for these other conditions. For example, most flammable materials and many materials which are normally regarded as non-flammable might burn vigorously under conditions of oxygen enrichment. These requirements are in addition to the requirements for installations in non-hazardous areas. This standard applies to all electrical equipment including fixed, portable, transportable and personal, and installations, permanent or temporary. This standard does not apply to – electrical installations in mines susceptible to firedamp; – inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing); – rooms used for medical purposes; – electrical installations in areas where the hazard is due to flammable mist. No account is taken in this Standard of the toxic risks that are associated with flammable gases, liquids and dusts in concentrations that are usually very much less than the lower explosive limit. In locations where personnel may be exposed to potentially toxic concentrations of flammable material, appropriate precautions should be taken. Such precautions are outside the scope of this Standard.
ÖVE/ÖNORM EN 60079-14
2014 11 01
Explosive atmospheres - Part 14: Electrical installations design, selection and erection (IEC 60079-...
Norm
ÖVE/ÖNORM EN 60079-14/AC
2012 03 01
Explosive atmospheres - Part 14: Electrical installations design, selection and erection (Corrigendu...
Norm
ÖVE/ÖNORM EN 60079-14/AC
2012 03 01
Explosionsfähige Atmosphäre - Teil 14: Projektierung, Auswahl und Errichtung elektrischer Anlagen (B...
Norm
ÖVE/ÖNORM EN 60079-14
2009 07 01
Explosive atmospheres - Part 14: Electrical installations design, selection and erection (IEC 60079-...
Norm
ÖVE/ÖNORM EN 60079-14
2009 07 01
Explosionsfähige Atmosphäre - Teil 14: Projektierung, Auswahl und Errichtung elektrischer Anlagen (I...
Norm
ÖVE/ÖNORM EN 61241-14
2005 08 01
Elektrische Betriebsmittel zur Verwendung in Bereichen mit brennbarem Staub - Teil 14: Auswahl und E...
Norm
ÖVE/ÖNORM EN 60079-14
2004 08 01
Elektrische Betriebsmittel für gasexplosionsgefährdete Bereiche - Teil 14: Elektrische Anlagen für g...
Norm
ÖVE/ÖNORM EN 60079-14
2000 07 01
Elektrische Betriebsmittel für gasexplosionsgefährdete Bereiche - Teil 14: Elektrische Anlagen in ex...
Norm
Historie aufklappen